Description
Rated power | 8000W | 10000W | 12000W | |
---|---|---|---|---|
Rated power | 8000W | 10000W | 12000W | |
BATTERY INPUT DATA | ||||
Battery type | Lead-acid battery / Lithium battery | |||
Battery voltage | 48V | |||
Battery voltage range | 40~60V | |||
Charging curve | 3-stage adaptive with maintenance/Equalization | |||
Charging Strategy for Li-lon Battery | Self-adaption to BMS | |||
Over-current protection/ Over-temperature protection | Yes / Yes | |||
Maximum charging/discharging power | 8000W | 10000W | 1000W | |
Maximum charging/discharging current | 190A | 210A | 240A | |
PV STRING INPUT DATA | ||||
Max. DC Input Power | 12000W | 15000W | 18000W | |
Rated PV Input Voltage | 550V | |||
Maximum DC voltage | 800V | |||
Start-up Voltage | 160V | |||
Minimum voltage for grid connection | 310V | |||
Full Load DC Voltage Range | 350-650V | |||
Enter high voltage error recovery point | 800V | |||
MPPT voltage range | 200~650V | |||
Maximum input current | 15A/15A | 26A/13A | ||
No.of MPP Trackers | 2 | |||
No.of Strings per MPP Tracker | 1+1 | 2+1 | ||
AC OUTPUT DATA | ||||
Rated AC Output Power | 8000W | 10000W | 12000W | |
Max AC Output Power | 8800W | 11000W | 13200W | |
AC Output Rated Current | 12.1/11.6A | 15.2/14.5A | 18.2/17.4A | |
Max AC Output Current | 13.4/12.8A | 16.7/15.9A | 20/19.1A | |
Max. Three-phase Unbalanced Output Current | 18.2/17.4A | 22.7/21.7A | 27.3/26.1A | |
Power Factor Adjustment Range | 0.8 leading to 0.8 lagging | |||
Rated Input/Output Voltage | 220/380,230/400Vac | |||
Rated Input/Output Grid Frequency/Range | 50/60;45~55/55-65 | |||
Grid Type | Three Phase | |||
Total Harmonics Current Distortion (THDi) | <3% (of nominal power) | |||
DC Current Injection | <0.5% In | |||
EFFICIENCY | ||||
≥97.5% | ||||
97.0% | ||||
PROTECTION | ||||
Integrated | PV Arc Fault Detection, Anti-islanding Protection, PV String Input Reverse Polarity Protection, Insulation Resistor Detection, Residual Current Monitoring Unit, Output Over Current Protection, Output Shorted Protection | |||
Surge Protection | DC Type III/AC Type III | |||
Overvoltage Category | DC Type II/AC Type III | |||
GENERAL DATA | ||||
Operating Temperature Range (°C) | -20°C to +60°C, >45°C Derating | |||
Cooling | Smart cooling | |||
Noise (dB) | ≤55dB | |||
Communication with BMS | Wi-Fi/USB/GPRS/RS485/CAN | |||
Machine Dimension (W*H*D)(mm) | 444*654.2*259.2 | |||
Package Dimension (W*H*D)(mm) | 816*404*567 | |||
N.W(kg) | 35 | |||
G.W(kg) | 37 | |||
Protection Degree | IP65 | |||
Installation Style | Wall-mounted | |||
Warranty | 5 Years the Warranty Period Depends the Final Installation Site of Inverter, More Info Please Refer to Warranty Policy | |||
CERTIFICATION & STANDARDS | ||||
CE-EMC+LVD (EN6100-6-3, EN6100-6-1+EN IEC 62109-1, EN IEC 62109-2); CE-LVD(EN 62477-1) ; IEC 60529; EN50549-1; Poland Type A, (NC RfG:2016, PSE:2018, PTPiREE:2021)C10/C11; UNE217001-2020; UNE217002-2020, NTS-631 (Type A); G98+G99